13903297993
hbblpj@126.comHot Search Words: Oil pump gasket Rubber products Other oil pump accessories Fly hammer & remove tools
Repair injector steps, injector gasket manufacturers for you to introduce it:
Step 1: test the injector on the test bed to see the test results.
Step 2: prepare gaskets of different thickness according to the proper range of armature lift (such as 45-55 micron).
Step 3: remove solenoid valve, simply measure armature lift, thicken or thin armature lift gasket thickness.
Step 4: test on the test bench to see if the test results are normal.
Step 5: if it is abnormal, replace the gasket and test on the test bench to see whether the test result is normal.
Step 6: if it is abnormal, continue to replace the gasket and test on the test bench to see whether the test result is normal.
Step 7: until the test result of the test bench is normal.